Excellent bias stability (less than0.15 mg)
Single power supply (+2.5V to +5.5V, ratiometric voltage output)
Low power
Extra small 20 pin LCC ceramic package with hermetic sealing (8.9mm x 8.9mm)
Individually calibrated (bias, scale factor and non-linearity)
Brown out protected
RoHS compliant suitable for lead free soldering process and SMD mounting
Parameters |
TS9001.D |
TS9002.D |
Units |
Full scale range |
± 1g |
± 2g |
g |
Bias calibration |
< 5 |
< 10 |
mg |
One year bias stability @ 6000g [1] |
0.75 (< 2.5) |
1.5 (< 5) |
mg typ. (max.) |
One year bias stability @ 1000g [2] |
0.15 (< 0.75) |
0.3 (< 1.5) |
mg typ. (max.) |
Switch on/off repeatability |
< 0.1 |
< 0.15 |
mg max. |
Bias temp. coefficient [3] |
< 0.05 |
< 0.1 |
mg/°C typ. |
± 0.2 |
± 0.4 |
mg/°C max. |
|
Scale factor sensitivity (K1) |
2000 ± 8 |
1000 ± 8 |
mV/g |
One year scale factor stability [1] & [2] |
300 (< 1000) |
300 (< 1000) |
ppm typ. (max.) |
Scale factor temp. coefficient [3] |
100 |
100 |
ppm / °C typ. |
-50 / 250 |
-50 / 250 |
min. / max. |
|
Input axis misalignment (Kp, Ko) |
< 10 |
< 10 |
mrad max. |
1 |
1 |
% max |
|
Resolution / Threshold (@ 1Hz) |
< 0.05 |
< 0.1 |
mg max. |
Non linearity |
< 1 |
< 0.8 |
% of FS max. |
< 0.01 |
< 0.02 |
g max. |
|
Bandwidth [4] |
0 to ≥ 100 |
0 to ≥ 100 |
Hz |
Noise spectral density in band |
18 |
18 |
mV/ÖHz typ. |
(0 ; 9kHz) |
24 |
24 |
max. |
Resonant frequency |
1.4 |
kHz |
[1]
One year stability defined according to IEEE 528-2001: turn on / on, storage at
-55°C and 85°C, -40°C to 125°C T cycling, -55°C to 85°C unpowered
harass, vibration, shock (6000g, single shock
in one axis).
[2]
One year stability defined according to IEEE 528-2001: turn on / on, storage at
-55°C and 85°C, -40°C to 125°C T cycling, -55°C to 85°C unpowered
harass, vibration, shock (1000g, single shock
in one axis).
[3]
Temperature coefficients are specified for a range of –40°C to 20°C, where
temperature behavior is typically linear and coefficient are maximum.
[4]
The bandwidth is defined as the frequency band for which the sensitivity has
decreased by less than 3dB.